Ontario Building Code Tools

    OBC Climate & Thermal Tool

    Find your project's climate zone and required thermal performance using the 2024 Ontario Building Code.

    Step 1 — Search your city

    Type any Ontario city or location. Climate data, zone classifications, and thermal requirements will update automatically below.

    ↓ Climate data cards update below · Scroll down for thermal compliance tables (SB-12 / SB-10)

    Step 2 — Climate data results

    General

    City / LocationAilsa Craig
    Elevation (m)230

    Rainfall

    15-min Rain (mm)25
    1-day 1/50 Rain (mm)103
    Annual Rain (mm)800
    Moisture Index0.90
    Annual Total Precip (mm)950

    Temperature

    January 2.5% (°C)-17
    January 1% (°C)-19
    July Dry Bulb 2.5% (°C)30
    July Wet Bulb 2.5% (°C)23
    Degree Days Below 18°C3840

    Snow Load

    Snow Load Ss 1/50 (kPa)2.20
    Snow Load Sr 1/50 (kPa)0.40

    Wind Pressure

    Driving Rain Wind 1/5 (Pa)180
    Hourly Wind 1/10 (kPa)0.37
    Hourly Wind 1/50 (kPa)0.48

    Seismic (Table 3)

    Sa(0.2) for Seismic Design in Part 90.10

    Climatic Zones (SB-10 / SB-12)

    SB-12 Rules

    • Zone 1: HDD18 < 5 000
    • Zone 2: HDD18 ≥ 5 000

    SB-10 Rules

    • Zone 5: HDD18 < 4 000
    • Zone 6: 4 000 ≤ HDD18 < 5 000
    • Zone 7: HDD18 ≥ 5 000

    Result for Ailsa Craig

    HDD18 = 3840

    SB-12 → Zone 1

    SB-10 → Zone 5

    Step 3 — Select your building type

    Choose the classification that matches your project. The thermal compliance table below will update accordingly.

    Construction

    Units:

    Thermal Performance — Additions to Existing Buildings

    SB-12 Table 3.1.1.11

    Zone: Zone 1 (HDD18 = 3840) → Zone 1 (< 5 000 HDD18)

    ComponentMin. Nominal RMax. U (Btu/(h·ft²·°F))Min. Effective RER
    Ceiling with Attic Space600.01759.22
    Ceiling Without Attic Space310.03627.65
    Exposed Floor310.03429.80
    Walls Above Grade19 + 5 ci0.04920.32
    Basement Walls20 ci0.04721.12
    Heated Slab / Slab ≤ 600 mm Below Grade100.09011.13
    Edge of Below-Grade Slab ≤ 600 mm10
    Windows & Sliding Glass Doors0.2825

    • Basement Walls: Alt.: R12 + 10 ci ↔ R20 ci; or R15 ci ↔ R12 + 5 ci.

    Nominal/Effective R in (h·ft²·°F)/Btu · U in Btu/(h·ft²·°F)

    Source: 2024 Ontario Building Code — SB-1 (Tables 2 & 3) · SB-12 Tables 3.1.1.2, 3.1.1.3, 3.1.1.11 · SB-10 Div.3 Tables SB 5.5-5/6/7 · SB-10 Div.5 Table 1.1.1.2

    Found this useful? Support our free tools.